Most striking result so far
- In one sentence, for someone arriving now: Before: after a stroke the arm stayed limited, and no implant could read and stimulate the brain in real time. After: the implant stimulates to rehabilitate movement and, without new surgery, also lets the person control a computer.
- What it did: in July 2025, at Harborview Medical Center (Seattle), it implanted Brain Interchange for the first time: two silicone sheets with electrodes over the stroke area and a controller on the skull that stimulates within milliseconds according to neural activity. In April 2026, the same implant, in the same patient, was also used to control a computer (Pong), without new surgery.
- What it means: an implant that is therapy and interface at the same time: the rehabilitation hardware is already there, and reading signal becomes software.
- Impact: it brings BCI closer to a reimbursable indication (stroke rehabilitation) instead of communication.
- Patient and reaction: Matt Kidd, a mechanic from the Seattle area with several strokes (the last about four years earlier) that limited one side of his body, was the first. There is no direct statement from him in the sources consulted.
- New quote: Jeffrey Ojemann (UW): “a watershed moment”; Jeffrey Herron: “The brain didn’t evolve to have devices implanted into it”; Hanbin Cho, who developed the algorithm, on the surgery: “It doesn’t feel real.”
Identity
CorTec
Freiburg im Breisgau, Germany
Where it sits in the field
Where it is
- 🇩🇪Freiburg Germany
headquarters, lab and factory - 🇺🇸Seattle, WA USA
Harborview (MRPICS study) - 🇺🇸Rochester, MN USA
Mayo Clinic (epilepsy)
Where the device is applied
Illustrative diagram; approximate position, not to scale.
What they try to treat
Patients identified in public material
No patient identified by name in the sources read. Anonymous participants are not listed.
Hospitals, universities and partners
Who invested
Four rounds with no public amounts.
WHAT'S NEWWhat's new through Nov 24, 2026
What appeared between Oct 16 and Nov 24, 2026: a preclinical durability result, confirmation of three patients and the components business.
- Oct 21, 2026CorTec electrodes record stable signals for more than four years verified
In two monkeys at Weill Cornell, 63 of the 64 contacts on a µECoG array were still recording after more than four years (day 1,361); the data were presented and published in the proceedings of the 10th Graz BCI Conference in Sep 2026. Why it matters: durability is the bottleneck of chronic implantation — and these electrodes use the same materials and processes as Brain Interchange. Source: company release, Oct 21, 2026 · Implantable Devices, Oct 23 - Nov 10, 2026CorTec shows the procedure and confirms three patients in Seattle the company says
A corporate video details the Brain Interchange implantation; the company confirms three participants in the NIH-funded stroke study at Harborview Medical Center. Why it matters: the study has gone from a single case to a surgical routine — a condition for phase 2 and for any pivotal study. Source: company post, Nov 10 - Nov 16–19, 2026COMPAMED and MEDICA: the company also sells components the company says
CorTec was at both Düsseldorf trade fairs promoting custom electrodes and active implants (cuff, percutaneous, grid, paddle) for partners. Why it matters: CDMO revenue is what sustains Brain Interchange's clinical phase inside the same company. Source: company post, Nov 12
01What CorTec does differently
Almost every other company in the field only reads (Neuralink, Paradromics, Synchron) or only stimulates (ONWARD, with the BCI bolted on separately). CorTec wants a single implant to do both, in a closed loop. The product is called Brain Interchange: fully implanted, wireless, bidirectional, for long-term use, with surface electrodes (AirRay) on the cortex, no needles in tissue.
In architectural terms: two thin silicone sheets on the cortical surface, a unit on the skull that communicates by radio through the skin and is charged by induction, 32 recording and stimulation channels, and it is not MRI-compatible. Spatial resolution is lower than needles, but it is the only device inspected here that listens and acts through the same hardware, chronically.
022025-2026: what happened
- May 2024FDA approves the IDE (G230003/A001) for the MRPICS post-stroke motor rehabilitation study. The company expected the first implant in Q3 2024; it came a year later.
- Jul 22, 2025First human implant at Harborview Medical Center, Seattle. PI Jeffrey Ojemann (University of Washington), co-PI Steven Cramer (UCLA); engineering with Jeffrey Herron.
- Feb 10, 2026Second implant, in the company's words “informed by promising results from the first participant”.
- Apr 2026FDA Breakthrough Device Designation for stroke motor rehabilitation; the company is also in the TAP program.
- Apr 29, 2026The first participant controlled a computer with thought alone and played Pong, about nine months after implantation, with the same hardware and no new surgery.
- Aug 2026Second Breakthrough, now for communication. The third patient had already been implanted since April 2026, when the company joined the FDA's TAP.
The same implant, in the same patient, was used first as therapy (stimulation to recover movement after stroke) and then as a readout channel to control the computer. If a rehabilitation implant is already there, adding BCI becomes a software and decoding problem, not a second surgery.
03What is still fragile
The study is a feasibility study, single-arm, unblinded, with up to 4 participants; the registry itself acknowledges that, with four subjects, the number of confounding variables will likely prevent extrapolating therapeutic results to the stroke population. The primary endpoint is safety: making sure use does not worsen the upper limb. No controlled result has been published. The account of volitional control (Pong) appeared in peer-reviewed proceedings of the 10th Graz BCI Conference on Sep 23, 2026: one participant, three sessions — feasibility, not a controlled trial.
“Fully implantable and wireless” does not mean permanent
It is true as architecture (no pedestal and no connector through the skin). But the implant is temporary by protocol: removed after about nine months in the UW study, and the registry describes 38 weeks implanted plus 16 of follow-up. Chronic users at home: zero.
Two-phase structure (from the CTO interview): up to 4 patients with pre-programmed open-loop stimulation during about six weeks of physiotherapy; 24 weeks of monitoring; two weeks closed-loop; then a phase 2 with 8 more patients closed-loop. There is also a parallel epilepsy study at Mayo Clinic (NCT05439655), with 13 patients enrolled according to the company.
The company says more than 50 CorTec cortical electrodes have already been implanted in humans over more than a decade, and cites more than 500 days of stable continuous operation (Scientific Data, 2025). In Oct 2026 it reported more than four years of stable signals from cortical electrodes in primates, peer-reviewed and still preclinical; the 2025 paper was not opened here, so the 500-day figure remains a company claim.
04Two businesses under one roof
CorTec GmbH (Freiburg, founded in 2010 as a spin-off from the University of Freiburg and the Bernstein Center) has one operation with revenue and another that is pre-commercial:
- Components and CDMO: custom electrodes and active implants for third parties (the company notes that the same hands build active implants for partners across the field): cuff, percutaneous, grid and paddle, hermetic encapsulation. The AirRay subdural electrodes have had 510(k) clearance since 2019; the Brain Interchange system is the part still investigational. Annual sales in the single-digit millions (CTO, Aug 2025).
- Brain Interchange: its own implant, in clinical evaluation.
Capital: Santo Venture Capital (the Strüngmann family, of Hexal) and LBBW Venture Capital, plus public support from BMBF and the European Union; the company refers to four rounds with no amounts disclosed. That suggests patient capital, but no amount, valuation or date was recovered. Headcount: 56 (municipal register) or 87 (PitchBook), in conflict.
Openings: the application portal showed only a spontaneous-application block, with no named vacancy. The portal raised a browser privacy warning, so absence of openings is not a conclusion.
05Why this matters for the field
- It creates a different adoption path: a stroke patient already has a reason to have the implant.
- It proves a discipline the field tends to forget: stimulating and reading in the same device requires synchronizing, separating artifact and closing the loop in real time.
- It is one of the few cases where capital mixes private investors and European public subsidy.
Still missing: a controlled functional stroke result, the full text of the Pong paper (only the metadata was read), any data on chronic home use, capital amounts and the phase 2 outcome.
SOURCESWhere this comes from
- CorTec: releases of Jul 29, 2025 (first implant), Feb 10, 2026 (second) and Apr 29, 2026 (Pong)
- ClinicalTrials.gov NCT06506279 (MRPICS, University of Washington) and NCT05439655 (Mayo Clinic)
- FDA IDE G230003/A001 (announced May 2024)
- CTO interview, Börsen-Zeitung (Aug 2025)
- CorTec/EQS, Oct 21, 2026 (electrode durability)
- Gkogkidis et al., Graz BCI Conference 2026, doi 10.3217/978-3-99161-093-9-101